Toxic & Refrigerant Gas Sensor Range
SST Controls range of NDIR toxic and refrigerant sensors cover hydrocarbon and HFO HFC and HCFC gases with more gases being added as they become available.
SIL2 approvals provides Functional Safety compliance for system integration and versions of ambient and flow through (aspirated) housings are available.
Fully temperature compensated and with voltage outputs (optional Modbus) these sensors are easy to fit and integrate into a system.
Inserted into our NDIR EXD housings provides a stainless steel industrial enclosure with the added benefit of hazardous area approvals.
EN 50271 & SIL2 (TÜV) APPROVED
IEC 60079-29-1 PERFORMANCE ATEX & IECEx certified (CESI)
ATEX/IECEx certificates: CESI11ATEX039U / IECEx CES 12.0008U
ATEX marking: II 2G Ex d IIC Gb, I M2 Ex d I Mb, I M1 Ex d+ia I Ma
IECEx marking: Ex d IIC Gb, Ex d I Mb, Ex d+ia I Ma

Gases | Range | Applications | Outputs | Part number | Datasheet | |
---|---|---|---|---|---|---|
![]() | CO2 | 0-2%/5%/20% vol | ATEX/ IeCEX and SIL2 rated 20mm CO2 sensor for ambient monitoring | 0.4V - 2.0V 0-100mV (option) Modbus RTU UART P2P | IRNEX-P-CO2 | ![]() ![]() |
![]() | CH4 | 0-100% LEL | ATEX/ IeCEX and SIL2 rated 20mm CH4 sensor for ambient monitoring (other hydrocarbons available) | 0.4V - 2.0V 0-100mV (option) Modbus RTU UART P2P | IRNEX-P-CH4 | ![]() ![]() |
![]() | C3H8 | 0-100% LEL | ATEX/ IeCEX and SIL2 rated 20mm Propane sensor for ambient monitoring (other hydrocarbons available) | 0.4V - 2.0V 0-100mV (option) Modbus RTU UART P2P | IRNEX-P-C3H8 | ![]() |
![]() | C3H8 | 0-2%vol / 0-100%LEL | 32mm Propane sensor (cross sensitivity table available for other hydrocarbons). | 0.4V - 2.0V Modbus RTU UART P2P | IRNET-P-C3H8 | ![]() |
![]() | CH4 | 0-100%vol / 0-100%LEL /0-5%vol | 32mm Methane sensor | 0.4V - 2.0V Modbus RTU UART P2P | IRNET-P-CH4 | ![]() |
![]() | R-134a | 0-2000ppm | 32mm Refrigerant sensor in ambient or flow thru housings | 0.4V - 2.0V Modbus RTU UART P2P | Ambient: IREFP-R134A Aspirated: IREFA-R134A | ![]() |
![]() | R-125 | 0-2000ppm | 32mm Refrigerant sensor in ambient or flow thru housings | 0.4V - 2.0V Modbus RTU UART P2P | Ambient: IREFP-R125 Aspirated: IREFA-R125 | ![]() |
![]() | R-404a | 0-2000ppm | 32mm Refrigerant sensor in ambient or flow thru housings | 0.4V - 2.0V Modbus RTU UART P2P | Ambient: IREFP-R404A Aspirated: IREFA-R404A | ![]() |
![]() | R-407a | 0-2000ppm | 32mm Refrigerant sensor in ambient or flow thru housings | 0.4V - 2.0V Modbus RTU UART P2P | Ambient: IREFP-R407A Aspirated: IREFA-R407A | ![]() |
![]() | R-407f | 0-2000ppm | 32mm Refrigerant sensor in ambient or flow thru housings | 0.4V - 2.0V Modbus RTU UART P2P | Ambient: IREFP-R407F Aspirated: IREFA-R407F | ![]() |
![]() | R-410a | 0-2000ppm | 32mm Refrigerant sensor in ambient or flow thru housings | 0.4V - 2.0V Modbus RTU UART P2P | Ambient: IREFP-R410A Aspirated: IREFA-R410A | ![]() |
![]() | R-417a | 0-2000ppm | 32mm Refrigerant sensor in ambient or flow thru housings | 0.4V - 2.0V Modbus RTU UART P2P | Ambient: IREFP-R417A Aspirated: IREFA-R417A | ![]() |
![]() | R-448a | 0-2000ppm | 32mm Refrigerant sensor in ambient or flow thru housings | 0.4V - 2.0V Modbus RTU UART P2P | Ambient: IREFP-R448A Aspirated: IREFA-R448A | ![]() |
![]() | R-449 | 0-2000ppm | 32mm Refrigerant sensor in ambient or flow thru housings | 0.4V - 2.0V Modbus RTU UART P2P | Ambient: IREFP-R449 Aspirated: IREFA-R449 | ![]() |
![]() | R-1234yf | 0-2000ppm | 32mm Refrigerant sensor in ambient or flow thru housings | 0.4V - 2.0V Modbus RTU UART P2P | Ambient: IREFP-R1234YF Aspirated: IREFA-R1234YF | ![]() |
![]() | R-1234ze | 0-2000ppm | 32mm Refrigerant sensor in ambient or flow thru housings | 0.4V - 2.0V Modbus RTU UART P2P | Ambient: IREFP-R1234ZE Aspirated: IREFA-R1234ZE | ![]() |
![]() | R-32 | 0-2000ppm | 32mm Refrigerant sensor in ambient or flow thru housings | 0.4V - 2.0V Modbus RTU UART P2P | Ambient: IREFP-R32 Aspirated: IREFA-R32 | ![]() |
![]() | R-507 | 0-2000ppm | 32mm Refrigerant sensor in ambient or flow thru housings | 0.4V - 2.0V Modbus RTU UART P2P | Ambient: IREFP-R507 Aspirated: IREFA-R507 | ![]() |
![]() | SF6 | 0-1000ppm / 0-2000ppm | 32mm Refrigerant sensor in ambient or flow thru housings | 0.4V - 2.0V Modbus RTU UART P2P | Ambient: IREFP-SF6 Aspirated: IREFA-SF6 | ![]() |
![]() | Ethylene | 0-100%LEL / 2.3%vol | 32mm Ethylene sensor in ambient or flow thru housings | 0.4V - 2.0V Modbus RTU UART P2P | Ambient: IREFP-C2H4 Aspirated: IREFA-C2H4 | ![]() |
![]() | CO2 | 0-5000ppm / 0-5%vol / 0-100%vol | 32mm precalibrated and configured sensor for CO2 with industrial outputs | 4-20mA & Modbus | CY-AIN-INP32-CO2-RANGE | ![]() |
![]() | Butane | 0-100%LEL | 32mm precalibrated and configured sensor for hydrocarbons with industrial outputs | 4-20mA & Modbus | CY-AIN-INP32-BUNL | ![]() |
![]() | Methane | 0-100%LEL | 32mm precalibrated and configured sensor for hydrocarbons with industrial outputs | 4-20mA & Modbus | CY-AIN-INP32-CH45 | ![]() |
![]() | Pentane | 0-100%LEL | 32mm precalibrated and configured sensor for hydrocarbons with industrial outputs | 4-20mA & Modbus | CY-AIN-INP32-PENL | ![]() |
![]() | Propane | 0-100%LEL | 32mm precalibrated and configured sensor for hydrocarbons with industrial outputs | 4-20mA & Modbus | CY-AIN-INP32-PRO2 | ![]() |
![]() | Propylene | 0-100%LEL | 32mm precalibrated and configured sensor for hydrocarbons with industrial outputs | 4-20mA & Modbus | CY-AIN-INP32-PRYL | ![]() |
![]() | iso-Butane | 0-100%LEL | 32mm precalibrated and configured sensor for hydrocarbons with industrial outputs | 4-20mA & Modbus | CY-AIN-INP32-BUIL | ![]() |
![]() | iso-Butylene | 0-100%LEL | 32mm precalibrated and configured sensor for hydrocarbons with industrial outputs | 4-20mA & Modbus | CY-AIN-INP32-BUYL | ![]() |
![]() | Dimethylether | 0-100%LEL | 32mm precalibrated and configured sensor for hydrocarbons with industrial outputs | 4-20mA & Modbus | CY-AIN-INP32-DMEL | ![]() |
![]() | Difluoroethane | 0-100%LEL | 32mm precalibrated and configured sensor for hydrocarbons with industrial outputs | 4-20mA & Modbus | CY-AIN-INP32-DFEL | ![]() |
![]() | R-134a | 0-2000ppm | 32mm precalibrated and configured sensor for refrigerants with industrial outputs | 4-20mA & Modbus | CY-AIN-INP32-R134A | ![]() |
![]() | R-125 | 0-2000ppm | 32mm precalibrated and configured sensor for refrigerants with industrial outputs | 4-20mA & Modbus | CY-AIN-INP32-R125 | ![]() |
![]() | R-1234yf | 0-2000ppm | 32mm precalibrated and configured sensor for refrigerants with industrial outputs | 4-20mA & Modbus | CY-AIN-INP32-R1234YF | ![]() |
![]() | R-404a | 0-2000ppm | 32mm precalibrated and configured sensor for refrigerants with industrial outputs | 4-20mA & Modbus | CY-AIN-INP32-R404A | ![]() |
![]() | R-407a | 0-2000ppm | 32mm precalibrated and configured sensor for refrigerants with industrial outputs | 4-20mA & Modbus | CY-AIN-INP32-R407A | ![]() |
![]() | R-410a | 0-2000ppm | 32mm precalibrated and configured sensor for refrigerants with industrial outputs | 4-20mA & Modbus | CY-AIN-INP32-R410A | ![]() |
![]() | R-507 | 0-2000ppm | 32mm precalibrated and configured sensor for refrigerants with industrial outputs | 4-20mA & Modbus | CY-AIN-INP32-R507 | ![]() |
![]() | SF6 | 0-2000ppm | 32mm precalibrated and configured sensor for refrigerants with industrial outputs | 4-20mA & Modbus | CY-AIN-INP32-SF6 | ![]() |
![]() | Ethylene | 0-100%LEL | 32mm precalibrated and configured sensor for Ethylene with industrial outputs | 4-20mA & Modbus | CY-AIN-INP32-ETYL | ![]() |
![]() | Fully encpapsulated 4-20mA and Modbus ATEX/IECEX transmitters can be found here | ![]() |